Description
Mediline laboratory refrigerators with Comfort electronic controllers are the ideal refrigeration solution for your laboratory. These laboratory fridges meet the exacting demands made of laboratory appliances. The temperature can be set from +3°C to +16°C. The forced-air cooling system in conjunction with the precision electronic controller ensures temperature consistency and uniform temperature distribution in the interior.
Explosion protection: ATEX 95
The ATEX 95 certification confirms that Liebherr laboratory fridges and freezers with explosion protection are appropriate for the storage of explosive and highly flammable materials within the meaning of EU Directive 2014/34/EU (ATEX).
Comfort Controller
The precision Comfort electronic controller with digital temperature display enables temperatures to be set to 0.1°C accuracy. Symbols indicate the operating status of the appliance at all times. To satisfy laboratory hygiene requirements, the Comfort electronic controller is flush-mounted and has an easy-clean membrane keypad.
Integrated alarm systems
A visual and audible temperature alarm alerts the user if temperature deviation limits are exceeded. The parameters for the temperature alarm can be individually set. In addition, a visual and audible door alarm is raised if the door is open for longer than 1 minute. Furthermore, the laboratory appliances with Comfort electronic controllers have a visual power failure alarm when mains power returns and a sensor defect alarm.
Integrated data memory
The Comfort electronic controller has an integrated data memory. It logs the maximum and minimum internal temperatures that occurred once the set temperature was reached, the last three temperature alarms and power failures, together with the time, date and duration of the alarm. The respective data can be recalled using the AlarmLog function and read on the display panel.
1-point calibration
The laboratory appliances with Comfort electronic controllers provide 1-point calibration for accurate temperature control. This permits compensation between the set temperature and the actual internal temperature. Positive or negative changes to the correction value can be made in steps of 0.1K.
Maximum temperature stability and temperature consistency
In conjunction with the precision Comfort electronic controller, the forced-air cooling system of this laboratory refrigerator ensures maximum temperature stability and high-temperature consistency. This laboratory refrigerator is equipped with a secondary safety thermostat to prevent temperatures below +2°C in case of a fault. All the laboratory appliances with Comfort electronic controllers are tested according to the NF X 15-140 standard with regard to maximum temperature stability and optimal temperature consistency.